8
2.3 I Electricity supply connecti on
• Connect the pump so that the mains power supply is never inadvertently interrupted when a
speed is being used. The speeds are monitored and controlled by the user interface or by the
external motor controller, and not by the mains power supply (see § "3.4.4 Timers").
• Before any any work on or inside the appliance you must disconnect the electricity supply to
avoid the risk of electric shock which may cause material damage, serious injury or even death.
• Only a qualifi ed and experienced technician is authorised to perform works, including cabling
work, or to replace the power cord.
• To prevent overheati ng of the terminal board, which could create a fi re hazard, check that all
terminals have been properly ti ghtened. Loose terminals will void the warranty.
• The appliance must be connected to the earth.
• Any unsuitable electrical connecti on will invalidate the warranty.
•
The pump will only start when commanded to do so via its user interface or via an external controller (for example
AquaLink® TRi or iQPUMP).
•
The appliance's electrical supply must be provided through a protecti on and circuit breaking device (not supplied)
complying with the standards and regulati ons in force in the country in which it is installed.
•
Electrical protecti on: by circuit breaker, with a 30 mA specifi c residual-current circuit breaker (circuit breaker or
switch) at the head of the line.
•
The power supply must correspond to the voltage indicated on the appliance's informati on plate.
•
The power cord must be insulated and protected against abrasions and damage.
•
Use the gland to pass the power cord into the appliance.
•
The appliance and the swimming pool and any other electrical equipment must be connected to the earth.
•
Open the electric box in front of the user interface (where present) by removing its screw.
•
Run the power cord through the gland and connect it to the terminals:
Power supply 230 Vac-50Hz
= connecti on to the terminals
(earth), L2/N (neutral) et L1 (phase)
•
Close the electric box and properly ti ghten its screw.