13
EN
2.5.2 Connecti on to AquaLink® TRi
• In order to prevent risk of electrocuti on, which can result in serious injury or loss of life,
check that the appliance has been disconnected from the power supply before performing
the following steps.
• Connecti ons to an RS485 terminal board: 1 = red ; 2 = black ; 3 = yellow ; 4 = green
• Do not cut the RS485 cable as this will prevent the user interface from being reconnected to
the pump and will make it impossible to restore the factory setti ngs. The cable is fi xed to the
pump and cannot be removed or extended.
• Never lay these low-voltage cables in the same pipe as high-voltage cables.
• The user interface (where present) becomes inacti ve if the pump is connected to the AquaLink®
TRi.
•
Open the electrical compartment in front of the user interface by unscrewing the screw and lift ing the cover.
•
Disconnect the RS485 terminal board and put it aside.
•
Connect the supplied RS485 cable extension between the AquaLink® TRi and the pump using the RS485 terminal
boards.
•
Refer to the AquaLink® TRi user and installati on manual to register and start using the pump.
1
OFF
2
OFF
3
OFF
4
OFF
5
ON
Positi on of the switches for control via AquaLink® TRi
Connecti on to AquaLink® TRi