background image

WWW.HAYWARDPOOL.COM              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

P/N:  ISSPSERIES 

REV. A  

 

   

 

 

 

__________________________________________________________________________________________ 
 

OWNER’S MANUAL 

INSTALLATION, OPERATION, & PARTS 

 
 

   

 

 

 

         

*50HZ Models are not UL or CSA Listed. 

 

 

Super Pump

 

Series 

 

The Hayward Super Pump

TM

 is specifically engineered for the demanding requirements of today’s in-ground swimming pool/spa that 

is equipped with large capacity filters, heaters, and pool cleaning equipment.  The Super is a self-priming pump that incorporates an 
improved seal and impeller design that will provide many years of efficient, dependable, corrosion-free service.  The advanced design 
provides superior performance while reducing maintenance requirements. 

 

To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.   

 

 

WARNING

 

 

This product should be installed and serviced only by a qualified professional.

 

 

CAUTION

 

 

A

 

licensed

 

electrician MUST complete, in full, all electrical installations noted in this manual.  

 

SAVE THIS INSTRUCTION MANUAL 

 

Use of non-Hayward replacement parts voids warranty. 

 
ATTENTION

 

INSTALLER

 

 

THIS

 

MANUAL

 

CONTAINS

 

IMPORTANT

 

INFORMATION

 

ABOUT

 

THE

 

 

INSTALLATION,

 

OPERATION,

 

AND

 

SAFE

 

USE

 

OF

 

THIS

 

PUMP

 

THAT

 

MUST

 

BE

 

FURNISHED

 

TO

 

THE

 

END

 

USER

 

OF

 

THIS

 

PRODUCT.  FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS 

INJURY. 

 
 
 

 

HAYWARD POOL PRODUCTS, INC. 

620 DIVISION STREET    ELIZABETH, NJ  07207    (908) 351-5400 

WWW.HAYWARDPOOL.COM

 

 

Summary of Contents for Super Pump

Page 1: ...ree service The advanced design provides superior performance while reducing maintenance requirements To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely WARNING This product should be installed and serviced only by a qualified professional CAUTION A licensed electrician MUST complete in full all electrical installations noted in this manual...

Page 2: ...the electrical components from the weather Select a well drained area one that will not flood when it rains It requires free circulation of air for cooling Do not install in a damp or non ventilated location If installed within an outer enclosure or beneath the skirt of a hot tub or spa adequate ventilation and free circulation of air must be provided to prevent overheating of the motor WARNING Po...

Page 3: ...d complying with the NEC the preceding four 4 hazards apply WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outlet covers which are damaged broken cracked missing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cover Limb Entrapment A limb inserted into an opening of a suct...

Page 4: ...alve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING This pump is not designed to be pressure tested However the remainder of the circulation system shall not be tested or operated at any higher pressure than 50 psi WARNING Fire a...

Page 5: ...odes Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints The base MUST be solid level rigid and vibration free Pump mount must Allow pump inlet height to be as close to water level as possible Allow use of short direct suction pipe to reduce friction losses Allow for gate valves in suction and discharge piping Be protected from excess moist...

Page 6: ... off old Teflon tape re wrap with one to two additional layers of Teflon tape and re install connector Fittings Fittings restrict flow For better efficiency use the fewest possible fittings but at least two suction outlets Avoid fittings that could cause an air trap Pool and spa fittings MUST conform to the International Association of Plumbing and Mechanical Officials IAPMO standards Use a non en...

Page 7: ...er bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool spa or hot tub and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING A licensed electrician must do all wiring Instructions for Electrician Install a Ground Fault Circuit Interrupte...

Page 8: ...ilure to do so may cause reverse rotation of motor and consequent serious pump damage Close filter manual air relief valve after pump is primed Maintenance Clean strainer basket regularly Do NOT strike basket to clean Inspect strainer cover gasket regularly and replace as necessary Hayward pumps have self lubricating motor bearings and shaft seals No lubrication is necessary Keep motor clean Insur...

Page 9: ...ionary sections of the two part replacement seal Foreign matter or improper handling will easily scratch the graphite and ceramic sealing surfaces Removing the Motor Assembly See Parts Diagram on page 11 of this manual for pump component locations 1 Remove the four 4 3 8 x 2 housing cap screws which hold the motor assembly to the pump strainer housing 2 Slide the motor assembly out of the pump str...

Page 10: ...lished side facing out Replacing the Impeller and Diffuser See Parts Diagram on page 11 of this manual for pump component locations 11 Place the seal plate onto the motor mounting plate aligning the tabs on the seal plate with the grooves on the motor mounting plate 12 Screw the impeller onto the motor shaft in a clockwise direction Tighten snugly by holding motor shaft with wrench as noted in ste...

Page 11: ...00R SPX1600R SPX1600R SPX1600R 9 DIFFUSER 1 SPX2600B SPX2600B SPX2600B SPX2600B SPX2600B SPX1616B 10 IMPELLER 1 SPX2600C SPX2605C SPX2607C SPX2610C SPX2615C SPX1621C 11 SEAL ASSEMBLY 1 SPX1600Z2 SPX1600Z2 SPX1600Z2 SPX1600Z2 SPX1600Z2 SPX1600Z2 12 HOUSING GASKET 1 SPX1600T SPX1600T SPX1600T SPX1600T SPX1600T SPX1600T 13 SEAL PLATE 1 SPX2600E5 SPX2600E5 SPX2600E5 SPX2600E5 SPX2600E5 SPX1611E5 14 MO...

Page 12: ...ousing is filled with water and cover o ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring is lubricated with Jack s 327 and that strainer cover is locked firmly in position Lubricant will help to create a tighter seal 2 Loose connections on suction side Solution Tighten pipe union connections NOTE Any self priming pump will not prime if there are suction air l...

Page 13: ...r leak in suction piping cavitations caused by restricted or undersized suction line or leak at any joint low water level in pool and unrestricted discharge return lines Solution Correct suction condition or throttle return lines if practical Holding hand over return fitting will sometimes prove this point or putting in a smaller eyeball fitting 2 Vibration due to improper mounting etc Solution Mo...

Page 14: ...press written authorization of Hayward Pool Products Inc To original purchasers of this pump Hayward Pool Products Inc warrants its pump housing strainer to be free from defects in materials and workmanship for a period of ONE 1 year from the date of purchase Pump housing strainers which become defective during the warranty period except as a result of freezing negligence improper installation use...

Page 15: ...____________ State_________ Zip____________ Company name________________________________________________ E mail Address__________________________________________ Address_______________________________________________________ City__________________________ State_________ Zip_______________ Product Purchased ______________________________________ Product Serial No ___________________________________...

Reviews: