manualshive.com logo in svg
background image

Please pass these instructions on to the operator of this equipment.

WARNING: 

Failure to follow these instructions and comply with all applicable 

codes may cause serious bodily injury and/or property damage.

The installation of this product should be carried out by a person knowledgable 

in swimming pool plumbing requirements following the installation instructions 

provided in this manual.

Typhoon

®

Whisper

®

WHISPER Series, 

TYPHOON C & T-Series 

Swimming Pool Pumps

Installation and Operating 

Instructions

Содержание WHISPER Series

Страница 1: ...s may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirements following the installation instructions provided in this manual Typhoon Whisper WHISPER Series TYPHOON C T Series Swimming Pool Pumps Installation and Operating Instructions ...

Страница 2: ...of these installation and operating instructions please contact your Davey dealer or the appropriate Davey office as listed on the back of this document The Davey Whisper and Tyhoon pool pumps have been designed to circulate swimming pool and spa water in conditions set out in the Australian Standard for swimming pool water quality AS 3633 or equivalent They should not be used for any other purpos...

Страница 3: ...lt consequences for which we decline all responsibility Installation The installation of our electric pumps is only permitted in swimming pools or ponds that meet DIN standards VDE 0100 part 702 11 82 In case of doubt inquire with an expert The pump should be installed as near as possible to water level in horizontal position in order to obtain a minimum suction path and reduce head losses It is n...

Страница 4: ...ld be structured with a slight slant to prevent the formation of siphons Electrical connection IMPORTANT INFORMATION Your Davey pump is Double Insulated to Water Circuit If equipotential bonding structure is required then a Equipotential Bonding Point is provided Please refer to your local statutes and regulations for AS NZ 3000 Wiring standards The electrical installation should have a multiple s...

Страница 5: ...nd their possible solutions provided in this manual NEVER RUN THE PUMP DRY Starting Open all the gate valves and put the motor under voltage Wait a reasonable time to allow self priming Verify the breakaway current and suitable adjust the thermal relay Maintenance WARNING Ensure that the pump is switched off from the supply mains before removing the cover Pumps are not to be plugged permanently to...

Страница 6: ...p it contains no toxic or contaminating materials The principal components are duly identified for selective breaking If the supply cord is damaged it must be replaced by the manufacturer or it s service agent or a similarly qualified person in order to avoid a hazard SINGLE PHASE SUPPLY Fig 1 ...

Страница 7: ...prime 2 Pump supplies scant flow 3 Pump noisy 4 Pump does not start 5 Motor makes sound but does not start 1 2 3 4 5 Problem Solution X X Air entry through suction line Verify condition of connectors and gaskets of suction linw X Inadequate airtightness of filter cover Clean the filter cover and verify condition of rubber gasket X X Motor turning direction reversed Reverse 2 phases of the supply X...

Страница 8: ...ty The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions listed above apply The customer will be notified of the warranty decision in writing and if found to be invalid the customer must organis...

Отзывы: