10
2.4.2 Remote user interface
•
This interface can be installed in another locati on using the supplied remote interface kit.
• In order to prevent risk of electrocuti on, which can result in serious injury or loss of life,
check that the appliance has been disconnected from the power supply before performing
the following steps.
• Connecti ons to an RS485 terminal board: 1 = red ; 2 = black ; 3 = yellow ; 4 = green
• Do not cut the RS485 cable as this will prevent the user interface from being reconnected to
the pump and will make it impossible to restore the factory setti ngs. The cable is fi xed to the
pump and cannot be removed or extended.
• Never lay these low-voltage cables in the same pipe as high-voltage cables.
: pump electric compartment
: pump RS485 terminal board
: pump RS485 cable
: user interface
: user interface RS485 terminal board
: cap to be unscrewed to positi on the cable
gland
Descripti on of the pump's technical compartment
: RS485 terminal board
: RS485 cable extension
: plasti c cover + foam gasket
: screws
: user interface wall mount
: grommet
Kit contents