16
3.4.4 Timers
• To prevent against any risk of material damage or injury, you are strongly encouraged to use
the "Timers" when the pump is not managed by an external controller, in order to ensure that
no speed is running in the event of a general power cut.
• "Timers" (programmes with scheduled pump start and stop ti mes) can be confi gured for
"eStar" speed and speed No. 2.
• "Timers" run in the same manner every day of the week.
•
To access the "Timer" programme, the speed that you want to programme must be running ("eStar" speed or speed
No. 2):
Speed LED
Clock display
Timer acti ve
Pump on
red
yes
Timer acti ve
Pump off
green
yes
Timer inacti ve
/
no
•
To deacti vate an acti ve Timer:
Tip: Timer operati on
•
2 Timers can be acti vated at the same ti me; the Timer with the highest speed will take priority.
•
The pump can be stopped manually when a Timer is running by pressing the butt on for the acti ve speed.
The Timer will resume normal acti vity during the next cycle.
•
If the pump is started manually, and a Timer is acti ve, it will stop at the end of the programmed Timer.