![background image](http://html1.mh-extra.com/html/zodiac/flopro-vs/flopro-vs_instructions-for-installation-and-use-manual_3998427014.webp)
12
2.4.3 Opti onal connecti on of an external "on/off " contact
•
You can connect an external dry contact to acti vate or deacti vate a speed in the case of a backwash or when using
a booster pump.
•
Access the printed circuit board at the rear of the user interface
.
•
Connect the contact to 2 terminals of the J3 connector: INPUT1, 2, 3 or 4 depending on the speed you
wish to acti vate using the contact (INPUT1 = speed 1, INPUT2 = speed 2, INPUT3 = speed 3, INPUT4 = speed 4).
: user interface
: external "on/off " contact
•
When the contact is closed, the regulati on interface will display:
and the pump
will start at the speed selected on the J3 connector.
•
Speed 4, by default known as
, is equipped with a 30-minute ti mer. When the contact is opened,
a countdown is displayed:
.
Tip: instructi ons to follow to connect an external "on/off " contact
•
To connect this functi on, the user interface must be remote in order to pass the cable through the
grommet on the base (see procedure § "2.4.2 Remote user interface").
•
In the case of connecti on to an AquaLink
®
TRi external controller, this functi on will be automati cally
proposed by the controller.
2.5 I Connecti on to an external controller
2.5.1 Connecti on to iQPUMP
• In order to prevent risk of electrocuti on, which can result in serious injury or loss of life,
check that the appliance has been disconnected from the power supply before performing
the following steps.
• Connecti ons to an RS485 terminal board: 1 = red ; 2 = black ; 3 = yellow ; 4 = green
• Do not cut the RS485 cable as this will prevent the user interface from being reconnected to
the pump and will make it impossible to restore the factory setti ngs. The cable is fi xed to the
pump and cannot be removed or extended.
• Never lay these low-voltage cables in the same pipe as high-voltage cables.
• The user interface (where present) becomes inacti ve if the pump is connected to the iQPUMP.
1
ON
2
ON
3
OFF
4
OFF
5
ON
Positi on of the switches for control via iQPUMP
•
To install and connect the iQPUMP, refer to the instructi on manual provided with the appliance.
Summary of Contents for FloPro VS
Page 2: ......
Page 7: ...5 EN 1 4 I Performance curves Flow rate Manometric head...