H0590700.B - EN - 2016-08
❷ Installati on
2.1 I Selecti ng the locati on
•
The fi lter must be installed:
-
aft er the circulati on pump,
-
before a heati ng and/or water treatment system,
-
ideally 0.5 m below the water level,
-
if it is to be installed indoors, it must be in a dry, well venti lated, frost-free equipment room.
•
The fi lter must not be installed:
-
in an area subject to fl ooding, splashing, rain or exposed to direct sunlight.
-
more than 1.5 m above the water level.
-
near a heat source or infl ammable gas,
-
in an equipment room where chemicals are stored, since any fumes could damage the fi lter.
•
It should be easily accessible for doing work (cover, hydraulic connecti ons, draining).
•
Allow total verti cal clearance of at least 1.35 m, in order to be able to open the fi lter and remove the cartridge easily.
•
The hydraulic circuit prior to the fi lter must be as short as possible and have as few obstacles as possible (elbows,
other devices), in order to prevent loss of head.
•
Install on a stable, solid, level surface (e.g. concrete fl oor).
•
Secure the fi lter to the ground using 6-8mm dia. x 60mm minimum stainless steel screws.
•
Install electrical control at least 1.5 meter from the fi lter. This will allow enough room to stand away the fi lter during
start-up.
1350 mm
Minimum horizontal clearance distances
Minimum verti cal clearance distance