background image

7

H0590700.B - EN - 2016-08

❸ Use

 3.1 I  Operati ng principle

The fi lter is essenti al for a swimming pool since it contributes to water treatment and ensures its clarity.

Water passes through the fi lter cartridge in the fi lter vessel and impuriti es are removed. 

The greater the accumulati on of impuriti es, the more the pressure in the fi lter will increase. When switching on the 

system, mark the normal operati ng pressure with the "CLEAN-DIRTY" ring on the pressure gauge. when the pressure 

r0.7 bar (10 psi) above normal operati ng pressure, the cartridge must be cleaned. 

 3.2 I  Operati on

• 

To prevent any risk of explosion that might cause damage to equipment, serious injury or 

even death, make sure that the hydraulic circuit is free of any debris or blockage and is not 

subject to excessive pressure and that the fi lter lid locking ring is properly installed.

• 

Ensure that all valves are open and/or that the power of the fi lter pump is suitable for the size 

of the fi lter if the initi al pressure is greater than 1.2 bar (17 psi).

• 

The fi lter cover must be correctly ti ghtened and its seal clean and in place (on the clamping ring inside the cover). If 

necessary, apply a silicone based lubricant to facilitate installati on.

• 

Check that the hydraulic connectors, ground fi xing screws, etc. are correctly ti ghtened,

• 

Ensure that the fi lter is properly stable; it should be level.

•  The hydraulic circuit must be bled and not contain any foreign bodies.

• 

Open the valves.

• 

Open the air release on the fi lter cover. 

• 

Stand clear of the fi lter and start the pump.

• 

When the water level in the fi lter is at maximum, water escapes through the air release, which should then be closed.

• 

Check that there are no leaks on the hydraulic circuit.

• 

Place the "CLEAN" arrow on the pressure gauge "CLEAN-DIRTY" ring on the value for the initi al pressure in the fi lter. 

The pressure should not exceed 1.2 bar (17 psi).

The "CLEAN" arrow positi on indicates the fi lter's initi al operati ng pressure and that the fi lter cartridge is clean.

Tip: installati on with a variable speed pump

• 

For an installati on with a variable speed pump, it is normal to have low initi al pressure if the fi ltering 

speed is low, and vice versa. In such a case, always use the same fi ltering speed as a comparison reference 

for the "CLEAN-DIRTY" indicati on.

EN

Summary of Contents for CS Series

Page 1: ...H0590700 B 2016 08 Instructions for installation and use English More documents on www zodiac poolcare com EN...

Page 2: ...er by recorded delivery letter In the event of a device containing coolant that tipping over state your reservations to the carrier in writing If the appliance su ers a malfunction do not try to repai...

Page 3: ...the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal injury and will void the warranty Save theses instructions during the de...

Page 4: ...seal x 2 E 63 50 mm dia union x 1 1 2 I Technical speci cations Unit CS 100 CS 150 Operating water temperature 1 to 40 C Filter area m 9 3 14 0 Maximum ow m h 22 7 28 4 Filtration speed m h m 2 4 2 1...

Page 5: ...0 370 470 80 510 330 510 360 Water intake Water outlet Draining Pressure gauge Air release Clamp ring dimensions in mm Front Top 1 4 I Graphs showing loss of head depending on ow rate 0 0 6 1 2 1 8 2...

Page 6: ...s could damage the lter It should be easily accessible for doing work cover hydraulic connections draining Allow total vertical clearance of at least 1 35 m in order to be able to open the lter and re...

Page 7: ...d discharge if it is installed below the water level Avoid high points on the pipework for more e cient priming Check that the hydraulic couplings are correctly tightened and that there are no leaks P...

Page 8: ...cover must be correctly tightened and its seal clean and in place on the clamping ring inside the cover If necessary apply a silicone based lubricant to facilitate installation Check that the hydraul...

Page 9: ...se operations are carried out by a technician and are chargeable 4 2 1 User maintenance Clean the outside of the equipment do not use solvent based products Check the lter pressure and the condition o...

Page 10: ...ensure that the bleed pipe is properly located inside it see para 4 2 3 Cleaning or replacing the lter cartridge Check the condition of the seal on the clamp ring inside the cover Replace it if it is...

Page 11: ...see para 4 2 3 Cleaning or replacing the lter cartridge The pump is not running quickly enough Adjust the pump speed to achieve a su cient ow variable speed pump only The water level in the pool is t...

Page 12: ...49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Trouvez plus d...

Reviews: