![background image](http://html1.mh-extra.com/html/zodiac/cs-series/cs-series_instructions-for-installation-and-use-manual_4001596011.webp)
H0590700.B - EN - 2016-08
10
❺ Troubleshooti ng
•
Before you contact your retailer, we invite you to carry out some simple checks for yourself
in
the event of a malfuncti on, using the following tables.
•
If the problem conti nues contact your retailer.
•
: Acti ons only to be carried out by a qualifi ed technician
The water is not clear.
•
Perhaps there is not enough disinfectant or the water balance is incorrect. Check
the water parameters (see "warnings and warranti es" booklet supplied with the
equipment).
•
The pool sees a lot of use. Check that the fi ltering ti me is suffi cient for the pool's level
of use.
•
The fi lter cartridge is dirty or holed. Clean or replace the fi lter cartridge (see para.
"4.2.3 Cleaning or replacing the fi lter cartridge").
Filter pressure too low
(see pressure gauge) /
low fl ow
•
The pump's pre-fi lter basket is full of debris; clean it.
•
Air leak in the circuit. Check that all joints are ti ght.
•
There is a blockage in the sucti on and/or discharge pipe. Check the hydraulic circuit.
•
Check the positi on of all valves in the hydraulic circuit.
•
There is a hole in the fi lter cartridge. Replace the fi lter cartridge (see para. "4.2.3
Cleaning or replacing the fi lter cartridge").
•
The pump is not running quickly enough. Adjust the pump speed to achieve a suffi cient
fl ow (variable speed pump only).
•
The water level in the pool is too low. Fill the pool.
•
The pump is not primed. Re-prime it.
•
The pump impeller and diff user are blocked or worn. Replace them.
Filter pressure too high
(see pressure gauge).
•
The fi lter cartridge is blocked. Clean or replace the fi lter cartridge (see para. "4.2.3
Cleaning or replacing the fi lter cartridge").
•
Check that the water balance parameters are correct (see "warnings and warranti es"
booklet supplied with the equipment).
•
The pump's pre-fi lter basket is broken. Replace it.
•
The pump fl ow exceeds the fi lter's nominal fl ow rate. Adjust the pump speed (on a
variable speed pump). For a single speed pump, check that the power is matched to
the fi lter.
The discharge water is
dirty.
•
There is a hole in the fi lter cartridge. Replace the fi lter cartridge (see para. "4.2.3
Cleaning or replacing the fi lter cartridge").
•
The fi lter has not been installed correctly. Check (see para. "❷ Installati on").
The pressure gauge
needle swings constantly.
•
Air leak in the circuit. Check that all joints are ti ght.
•
There is a blockage in the sucti on and/or discharge pipe. Check the hydraulic circuit.
•
Check the positi on of all valves in the hydraulic circuit.