 4.2.3 Cleaning or replacing the fi lter cartridge

• 

When the pressure gauge needle is close to the "DIRTY" arrow, the fi lter cartridge should be cleaned.

The "DIRTY" arrow positi on indicates that the pressure in the fi lter has increased in relati on to its initi al operati ng 

pressure and that the fi lter cartridge is dirty.

• 

Change the fi lter (see para. "4.2.2 Drain the fi lter").

• 

Remove the fi lter cover by pressing the locking tab on the fi lter body and unscrewing the clamp ring in an anti -

clockwise directi on.

• 

Remove the fi lter cartridge by pulling it upwards.

• 

Clean the fi lter cartridge with a hose pipe (do not use a high pressure jet), directi ng the water jet inside and then 

rinsing the outside. Use a soft  brush, if necessary.

• 

To clean off  algae, sun tanning oils and lime scale, soak the fi lter cartridge in a degreasing solvent and then in a de-

scaler. Ask your retailer for the appropriate products.

• 

Once the cartridge is clean, replace it in the fi lter body or insert a new cartridge, if necessary.

• 

Push the fi lter cartridge fi rmly into its housing and ensure that the bleed pipe is properly located inside it (see para. 

"4.2.3 Cleaning or replacing the fi lter cartridge").

• 

Check the conditi on of the seal (on the clamp ring inside the cover). Replace it if it is damaged. If necessary, apply a 

silicone based lubricant to facilitate installati on.

• 

Switch on the fi lter (see para. "3.2 I  Operati on").

Tip: cleaning the fi lter cartridge

• 

It is easier to clean a fi lter cartridge when it is dry. Simply tap it to remove most of the dirt. It can then 

be cleaned with water. In such a case, it may be worthwhile having a second cartridge, so that they can 

be alternated.

 4.2.4 Cleaning the bleed pipe

• 

Drain the fi lter (see para. "4.2.3 Cleaning or replacing the fi lter cartridge").

• 

Remove the fi lter cover by pressing the locking tab on the fi lter body and unscrewing the clamp ring in an anti -

clockwise directi on.

• 

Check that the bleed pipe inside the reservoir is not obstructed; if necessary, remove it and unblock it.

• 

Once the bleed pipe has been cleaned, replace it in the fi lter body and then replace the fi lter cartridge.

• 

Check the conditi on of the seal (on the clamp ring inside the cover). Replace it if it is damaged. If necessary, apply a 

silicone based lubricant to facilitate installati on.

• 

Switch on the fi lter (see para. "3.2 I  Operati on").

EN

Summary of Contents for CS Series

Page 1: ...H0590700 B 2016 08 Instructions for installation and use English More documents on www zodiac poolcare com EN...

Page 2: ...er by recorded delivery letter In the event of a device containing coolant that tipping over state your reservations to the carrier in writing If the appliance su ers a malfunction do not try to repai...

Page 3: ...the warnings and warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal injury and will void the warranty Save theses instructions during the de...

Page 4: ...seal x 2 E 63 50 mm dia union x 1 1 2 I Technical speci cations Unit CS 100 CS 150 Operating water temperature 1 to 40 C Filter area m 9 3 14 0 Maximum ow m h 22 7 28 4 Filtration speed m h m 2 4 2 1...

Page 5: ...0 370 470 80 510 330 510 360 Water intake Water outlet Draining Pressure gauge Air release Clamp ring dimensions in mm Front Top 1 4 I Graphs showing loss of head depending on ow rate 0 0 6 1 2 1 8 2...

Page 6: ...s could damage the lter It should be easily accessible for doing work cover hydraulic connections draining Allow total vertical clearance of at least 1 35 m in order to be able to open the lter and re...

Page 7: ...d discharge if it is installed below the water level Avoid high points on the pipework for more e cient priming Check that the hydraulic couplings are correctly tightened and that there are no leaks P...

Page 8: ...cover must be correctly tightened and its seal clean and in place on the clamping ring inside the cover If necessary apply a silicone based lubricant to facilitate installation Check that the hydraul...

Page 9: ...se operations are carried out by a technician and are chargeable 4 2 1 User maintenance Clean the outside of the equipment do not use solvent based products Check the lter pressure and the condition o...

Page 10: ...ensure that the bleed pipe is properly located inside it see para 4 2 3 Cleaning or replacing the lter cartridge Check the condition of the seal on the clamp ring inside the cover Replace it if it is...

Page 11: ...see para 4 2 3 Cleaning or replacing the lter cartridge The pump is not running quickly enough Adjust the pump speed to achieve a su cient ow variable speed pump only The water level in the pool is t...

Page 12: ...49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Trouvez plus d...

Reviews: