ZMC432N Motion Controller User Manual V1.5
Chapter III Wiring, Communication
Configuration
3.1.
Power Input
The power supply input adopts a 3Pin (there are all 3 terminals, E+24V, EGND and FG)
screw-type pluggable wiring terminal, and the interval (means the gap distance between
two ports, namely, between E+24V and EGND) should be 3.81mm. This 3Pin terminal is
the power supply of the controller.
When wiring, please don’t connect to all EGND signals
together.
→
Terminal Definition:
Terminal
Name
Type
Function
E+24V
Input
Power 24V input
EGND
Input
Power supply ground
FG
Earthing (Grounding)
Case protection
3.1.1.
Power Specification
→
Specification
Item
Description
Voltage
DC24V(-5%~5%)
The current to open
≤0.5A
The current to work
≤0.4A
Anti-reverse connection
Valid
Overcurrent Protection
Valid