SWT
GIGABIT/FAST ETHERNET SWITCH TYPE SWT
12/137
USER GUIDE - M0SWTA1903Iv09 - V09 March 2019
•
Block of
4
or
8
ports type
100Base-Fx multimode
(1300 nm) with
LC
connector.
•
Block of
4
or
8
ports type
100Base-Lx singlemode
(1300 nm) with
LC SM
connector.
•
Block of
2
or
4
ports type
100Base-Fx multimode
(1300 nm) with
SC
connector.
The blocks must be installed consecutively, from left to right, without leaving empty
slots.
If there are electrical ports, they must always be in the first position.
If only fiber optic ports are used, a maximum of 24 ports are supported.
No port blocks with 4 connectors MT-RJ, 2 connectors ST, 2 connectors SC or
4 connectors LC (LC SM) should be installed in the first position.
➢
1 service console (DCE mode).
➢
4 Gigabit Ethernet SFP bays (see section 1.4.3,
Accessories
), front or rear.
➢
1 I/O connector with one digital input and output that can be managed via SNMP.
The digital output can be configured as an alarm.
1.4.3
Accessories
➢
Gigabit/Fast Ethernet SFP modules.
The following list corresponds to verified modules, which comply with the temperature criteria.
•
SFP 1000BaseT (4CZ07980001)
type of connector: RJ-45
•
SFP 1000BaseSx (4CZ07980002)
type of connector: LC
type of fiber: multimode
wavelength: 850 nm
typical maximum distance: 550 m
•
SFP 1000BaseZx (4CZ07980004)
type of connector: LC
type of fiber: singlemode
wavelength: 1530 nm
typical maximum distance: 80 km
•
SFP 1000BaseLx (4CZ07980005)
type of connector: LC
type of fiber: singlemode
wavelength: 1310 nm
typical maximum distance: 10 km
•
SFP 100BaseEx (4CZ07980008)
type of connector: LC
type of fiber: singlemode
wavelength: 1310 nm
typical maximum distance: 40 km