![ZIV SW3-L3 User Manual Download Page 155](http://html1.mh-extra.com/html/ziv/sw3-l3/sw3-l3_user-manual_3847863155.webp)
SW3-L3
GIGABIT/FAST ETHERNET SWITCH/ROUTER TYPE SW3-L3
155/180
USER GUIDE - M0SW3M1902Iv07 - V06 February 2019
In the case of wanting to change the value of any attribute
in the item of a matrix-type parameter, the argument must
include the parameter name, the item number and the
attribute number.
Special attention should be paid when entering the
arguments of this command, as if no argument is
indicated the system will request the new value of each
of the parameters in the active directory and its
subdirectories, one by one. Consequently, if the
set
command is executed without an argument in the root
directory, the system will request a new value for all the
equipment configuration parameters.
If the
set
command is applied to a matrix-type parameter
without indicating the attribute to be modified, the
system will request a new value for each attribute of the
indicated item. If the item number is omitted, the new
values entered for each attribute will be applied to the
last item in the matrix.
Examples
:
swt /main>
set hostname
swt />
set main/hostname
swt /admin>
set ../main/hostname