5.1.3
Others
This section deals with three parameters. The first of them selects the hour zone in relation
to UTC.
The second parameter,
Enable periodic reset
, allows users to indicate whether they want
to reboot the equipment automatically every so often. This is selected in days through the
last parameter,
Periodic reset period
.
5.1.4
Syslog
This section deals with four parameters. The first of them,
Local Syslog Level
, selects the
maximum level of severity which is stored in the local Log. Valid values are 1 to 8. The
default value is 4.
The levels involve storing all information tagged with a level equal to or lower than the level
specified.
The levels are:
Level
Description
Emergency
: Level
1
Multiple apps/servers/sites. This level should not be used by
applications.
Alert
. Level
2
Should be corrected immediately. An example might be the
loss of the primary ISP connection.
Critical
. Level
3
May be used to indicate a failure in the system’s primary
application.
Error
. Level
4
An application has exceeded it file storage limit and attempts
to write are failing.
Warning
. Level
5
May indicate that an error will occur if action is not taken. For
example, a non-root file system has only 2GB remaining.
Notice
. Level
6
Events that are unusual but not error conditions.
Informational
. Level
7
Normal operational messages -no action required. For
example, an application has started, paused or ended
successfully.
Debugging
. Level
8
Info useful to developers for debugging the application.