SIP-2
99/145
USER GUIDE - Rev. 3 (January 2018)
Dialling Table:
•
Enable.
It establishes if the table should be used for the translation of the
numbering plan of the calls made with the ATDT command, or not.
•
#.
It is a sequence identifier provided by the equipment itself.
•
Telephone Number.
The number of the numbering plan related to the register.
•
Destination IP.
The destination IP address for the number specified in the previous
parameter.
•
TCP Port.
The destination TCP port for the number specified in the telephone
number parameter.
5.18
REBOOT
The equipment can be rebooted by executing the
Reboot
command, through the console
or through the HTML pages. The command is available only for the administrator profile.
5.19
CODE REFLASH
The equipment admits the updating of applicative software by executing the
Reflash
command, which is only available in the HTML pages and for the administrator profile.
The code reflash process does not alter the configuration data, unless this is expressly
indicated. Nevertheless, once terminated, it entails a momentary loss of service due to
the automatic rebooting of the equipment.
A binary images that is appropriate for the equipment is necessary, which can be selected
by pressing the button
Examine
.
After having selected the image, the update is executed by pressing
Reflash
. The process
usually takes about 5 minutes, during which time the results of the different steps are
displayed in the HTML browser window, but depending on the browser, it is possible that
only the result at the end of the process is shown.
The
Only verify
option allows users to check that the code saved is coincident with the
binary image selected without affecting the installed image.