SIP-2
16/145
USER GUIDE - Rev. 3 (January 2018)
1.4.9
Mechanical characteristics
➢
Dimensions: Height: 150 mm (with no cover for wires); Width: 40 mm; Depth: 177 mm.
➢
Weight: 600 g.
➢
DIN rail mounting (by means of optional accessory) or wall mount.
➢
IP protection level: IP 51.
➢
Material: varnishing (RAL 9006) aluminium 6060 T5 alloy and Fireproof (UL 94 V0)
STAREX ABS VH-0800 (RAL 7024) plastic.
1.4.10
Operating conditions
➢
Power supply: 48 Vdc (19-75 Vdc) isolated, 12 Vdc (10.5-15 Vdc) isolated or Universal
(88-300 Vdc, 88-265 Vac).
In DC supply-voltage operation the equipment is protected against polarity inversion.
➢
Maximum power consumption at 48 Vdc: 3.5 W.
➢
Temperature range: -40ºC to +70ºC.
➢
Relative humidity not greater than 95%, in accordance with IEC 721-3-3 class 3K5
(climatogram 3K5).
➢
R.F. emissions: in accordance with EN 55022 standard.
➢
Dielectric strength: in accordance with EN 60255-5 standard.
➢
Electromagnetic compatibility.
•
Electrostatic discharge immunity test:
in accordance with EN 61000-4-2 standard.
•
Radiated, radio-frequency, electromagnetic field immunity test:
in accordance with EN 61000-4-3 standard.
•
Electrical fast transient/burst immunity test:
in accordance with EN 61000-4-4 standard.
•
Surge immunity test:
in accordance with EN 61000-4-5 standard.
•
Immunity to conducted disturbances, induced by radio-frequency fields:
in accordance with EN 61000-4-6 standard.
•
Power frequency magnetic field immunity test:
in accordance with EN 61000-4-8 standard.
•
Damped oscillatory wave immunity test:
in accordance with EN 61000-4-18 (EN 61000-4-12) standard.
•
Voltage dips, short interruptions and voltage variations immunity tests:
in accordance with EN 61000-4-11 standard.