Log
/
Log all
They show the list of events taking place in the equipment. This command is
useful for monitoring the equipment and detecting potential errors during
operation.
Syntax
:
drn />
log
[
all
]
Arguments
:
-
Without arguments, this command shows the events
recorded in the equipment’s non-volatile memory.
all
(Optional) Shows all the events taking place in the
equipment in real time until the user presses a key.
Observations
:
All the events taking place in the equipment are stored in
a memory buffer with sufficient capacity for 100 records
and if an important event occurs (starting of sessions,
changes in configuration, etc.) this is recorded in the
equipment non-volatile memory which also has capacity
for 100 records.
Both the buffer and non-volatile memory are of the
circular type, i.e., once the memory is full, the oldest
event is removed every time a new event occurs.
Operationally two logs are created, which is permanent
(
log
command) and having temporal and global (
log all
command).
You can filter at will the temporary log, using the text as a
filter after the command. This operation works with any
text in the filter, not only with the category (see section
Information in the log
), so it is possible to filter traces of
individual processes or selected events
.
Example
:
drn />
log
drn />
log all
drn />
log crit
drn />
log debug