SIP-2
37/145
USER GUIDE - Rev. 3 (January 2018)
The factory IP address of the equipment is 192.168.0.1, meaning it is possible to access
the HTTP server to configure it from the very start.
If the IP address of the SIP-2 equipment (server) is modified, the IP address of the client
equipment (computer) must be consequently modified.
If the SIP-2 equipment and the computer are connected directly or through a LAN (they
belong to the same network), the IP address of each of them must have the same network
number and a different host number, so the subnet mask must be the same for both. The
default gateway does not need to be configured.
If the SIP-2 equipment and the management computer belong to different LANs and the
connection between them is via WAN, their IP addresses may have a different network
number, but both must be connected to some device (default gateway) capable of
interconnecting LANs.
Next chapter describes the parameters of the HTML pages, and in FIGURE 18 is shown
the tree menu.
For information about the
Reboot
and
Reflash
commands see sections 5.18 and 5.19,
respectively.
The
Apply
,
Save
and
Reboot
commands request confirmation of the operation from the
user before it is actually executed.