801910 v3.05 09.20 HT BCS Commercial Instructions
Page 23 of 32
Section 5
Filter / Softener Installation
An optional, external limescale filter / softener may be fitted to reduce the incidence of scale build up in the
hot tank.
•
Choose a suitable location, (cupboard back or side wall)
within the reach of the braided hoses.
•
Mount the filter head bracket in an upright position, using
the screws supplied in the kit.
•
Allow a min 80mm base clearance for the filter cartridge to
be easily fitted and removed.
•
Attach the hoses as shown, noting the flow directions as
marked on the filter head.
5.1
Mounting the filter head
*Min. 80mm
Clearance
5.2
Cartridge Installation
1. Unpack replacement cartridge. Write today’s date where
shown on the label and remove the sanitary cap.
2. Avoid touching the filter O-rings and filter opening as this
may cause bacterial contamination of the cartridge.
3. Moisten the O-rings with water, align the front cartridge
label to the left and push the new cartridge into the filter
head.
4. Turn the cartridge a quarter turn to the right until the
cartridge comes to a complete stop, with the front label
facing forward.
5. Disconnect the filter outlet hose from the Command Centre
and direct the hose end into a container ready for flushing.
6. Turn the power and water ON and depress the tap’s
Boiling lever and allow water to run for 30 seconds to flush
the tank.
7. Allow at least 10L to flow through the filter to ensure all
carbon particles have been flushed.
8. Turn the power and water off (after flushing 10L).
9. Reconnect the filter outlet hose to the Command Centre.
10. Turn the water supply back on and check for leaks.
11. Set the appropriate selection on the Internal Filter Bypass
valve located at the rear of the unit in accordance with
Sections 3.1 and 3.2.
Filter Label
Inlet
Outlet