801910 v3.05 09.20 HT BCS Commercial Instructions
Booster Installation
4.4
Braided hose connections
1. Remove the bypass loop from the top of the Command Centre.
2. The cold water inlet (blue) and hot water outlet (red) are marked on the rating plate. Connect the
braided hoses from the ‘Bypass Out’ fitting to the water inlet of the booster unit (marked blue), and
from the outlet of the booster unit (marked red) to the ‘Bypass IN’ fitting on the Zip HydroTap unit.
Avoid exerting any mechanical pressure on the appliance. This can be achieved by applying a spanner
on the flats of the inlet and outlet connections when tightening the braided hose connectors. Do not
over tighten! Tighten the braided hoses by hand, then turn an additional 90° - 180° with a spanner
3. Once the water connections have been made, check for any leaks and rectify as necessary.
Hot Water
Connection
(outlet, G1/2”)
Strainer
Cold Water
Connection
(inlet, G1/2”)
Hold the hexagon while
tightening the braided
hose fittings
Braided Hoses
Typical Installation