Important Safety Instructions
WARNINGS
1. The Zip HydroTap unit must be earthed. The resistance of the earth connection from
each exposed metal part must be less than 1 ohm.
2. All Installation and service work must be completed by trained and suitably qualified
Tradespeople. Faulty operation due to unqualified persons working on this product, or
any other Zip product may void warranty coverage.
3. Plumbing and electrical connections must be made in accordance with local regulations and relevant
standards. In Australia and New Zealand: Plumbing standard AS/NZS 3500 & Electrical Wiring Rules
AS/NZS 3000.
4. This HydroTap product is rated for 230V 50Hz AC operation.
5. This unit must be installed with adequate clearances of 50mm on all sides, and 200mm above, to allow
for air circulation. Additional means of ventilation is critical if the vent kit, as supplied, cannot be fitted.
6. Flush water supply lines before any plumbing connections are made, to prevent sediment from
affecting operation.
7. The Command Centre must not be located near, or cleaned with water jets.
8. This product is designed for indoor use and must not be installed outdoors or exposed to the elements
of nature.
9. For safe operation, the HydroTap is designed to be installed, commissioned and used within 48 hours.
Should the HydroTap not be required for an extended period of time (72 hours or more), do not fill and
commission the HydroTap until ready for first use.
10. For water taste and quality reasons, following any non-use period of more than 72 hours, Zip
recommends to perform a system flush. Failure to flush the system may affect water quality.
11. Due to the process of continuous improvement, Zip Water reserves the right to change details
mentioned in this manual, without notice.
2.64 kg CO
2
Cylinder Warnings:
•
Pressurised container.
•
Protect from sunlight.
•
Contains gas under pressure, may explode if heated.
•
Do not expose to temperatures exceeding 50˚C.
•
Do not pierce or burn, even after use.
•
Do not expose to naked flame or any incandescent material.
•
Keep out of reach of children.
•
High concentration of gas may cause asphyxiation.
•
Use only in ventilated areas.
•
Store in a location with a volume of no less than 50 cubic meters for each
2.64 kg bottle.
•
Use only in an upright position.
•
This bottle must be used with the approved pressure regulator.
•
Avoid shock.
•
Use according to MSDS (Material Safety Data Sheet).
Positioning
It is important to ensure the Command Centre is positioned in an accessible area close to the floor level. The unit must
have its base mounted in a horizontal position with all inlets and outlets facing up. The Tap must be located above the
Command Centre. See section 1 for details.
!