IMPORTANT SAFETY INSTRUCTIONS

This manual contains important safety and installation instructions for the Zip HydroTap. 

Please read all warnings, installation requirements and installation instructions before 

installing any Zip HydroTap. This system must be installed in accordance with water 

supply byelaws, current IEE regulations and relevant local authority byelaws.

Safety

This appliance is not intended for use by children under 8 years. Or persons (including 

children under 8 years) with reduced physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they have been given supervision or instruction concerning the use of the 

appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play 

with the appliance. 

Qualifications 

If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all installation 

procedures must be carried out by a suitably qualified tradesperson. The power cable and power outlet must be in a 

safe visible position for connection.

Venting

 

Sometimes steam and / or boiling water may discharge through a vent outlet on the tap. If the tap is not installed 

using the font, ensure the tap body is located so the tap outlet & vent safely dispense into the sink bowl area. 

Lifting

Take care when lifting. The Command Centre may exceed safe lifting limits. If you feel this is beyond your personal 

capabilities, please seek assistance with the lift. Do not lift the Command Centre by the front cover or any of its 

connections. Refer to the technical specification, see page 8

,

 for the weight of the product.

Airflow

The Zip HydroTap

 

operates within the ambient temperature range 5ºC - 35ºC. Proper air circulation must be 

provided. The system will operate satisfactorily only if the recommended air gaps are provided. See Section 1 

Ventilation, page 10, for correct installation to prevent overheating. 

Frost protection

If the HydroTap is located where the ambient air temperature could fall below 5ºC when the heater is not in use, do 

not turn off the appliance electrically. This safeguard does not offer the same protection to the connecting pipework 

and fittings.

o

Positioning

 

It is important to ensure the Command Centre is positioned in an accessible area close to the floor level. The 

Command Centre

 

must have it’s base mounted in a horizontal position with all inlets and outlets facing up. The tap 

must be located above the Command Centre. See  Section 3, Command Centre

 

installation

Warnings

• 

  The Zip HydroTap

 

must be earthed. The resistance of the earth connection from each 

exposed metal part must be less than 1

Ω

.

• 

All installation and service work must be completed by trained and suitably qualified 

!

WARNINGS & REGULATORY INFORMATION

!

Summary of Contents for HYDROTAP 2500UK

Page 1: ...AL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK ZIP HYDROTAP INSTALLATION INSTRUCTIONS USER MANUAL MODEL NUMBER 2500UK 2501UK Filtered boiling and ambient drinking w...

Page 2: ...5 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK The HydroTap series offers a range of interchangeable taps to suit the customer s needs Arc range Celsius Arc range These standalone ta...

Page 3: ...arrangements Step 2 Check for adequate ventilation Section 1 Ventilation 1 1 Ventilation for all models 10 Step 3 Install the filter tap Section 2 Filter system tap installation 2 1 Installing the fi...

Page 4: ...o a wholesome water supply Check the Command Centre rating plate and ensure correct power is available Check the under counter cupboard floor supporting the Command Centre is adequate for its total we...

Page 5: ...ap mounted on a sink or worktop which has been designed for residential applications The HydroTap utilises an immersion heating element to boil the water These boiling models will dispense boiling wat...

Page 6: ...led using the font ensure the tap body is located so the tap outlet vent safely dispense into the sink bowl area Lifting Take care when lifting The Command Centre may exceed safe lifting limits If you...

Page 7: ...water jets Do not expose the Zip HydroTap to the elements of nature Due to the process of continuous improvement Zip reserves the right to change details mentioned in this manual without notice Visit...

Page 8: ...ered Boiling 1 8 1x13A 1 50 216 x 272 x 338 6 5 Min Max water supply pressure Arc and Cube HydroTaps 0 17 MPa 1 7 bar 0 5 MPa 5 0 bar Celsius mixer taps 0 17 MPa 1 7 bar 0 5 MPa 5 0 bar Filter 0 17 MP...

Page 9: ...required The Command Centre must be installed in accordance with IEE regulations See Technical specification page 8 for power ratings Note Check all cable and hose lengths against inlet outlet positio...

Page 10: ...ated in the specification sheets and installation instructions must be observed Adequate ventilation must be provided to ensure that the cupboard space temperature does not exceed 350 C 1 2 Preferred...

Page 11: ...ter through the supply line thoroughly before connection Connect the pressure limiting valve to the isolating valve not supplied Mount the filter head and connect the stop cock in a convenient positio...

Page 12: ...tic pipe and connect it to the ambient outlet located on the top of the Command Centre ambient models only Measure and trim the CLEAR silicone tube and connect it to the vent outlet located on the top...

Page 13: ...ET RED CLEAR BLUE AMBIENT OUTLET BLUE Note Electrical power cable length is 3 0m Position the Command Centreaccording to the hose and cable lengths supplied Note All silicon tubes plastic pipes to the...

Page 14: ...m 50mm 535mm Note Electrical power cable length is 3 0m Position the Command Centreaccording to the hose and cable lengths supplied Note All silicon tubes plastic pipes to the taps must be cut to size...

Page 15: ...ck the water is clear with no soapy looking bubbles from the residue of the factory sanitisation process 4 3 Filter replacement For safe operation the filter cartridge should be replaced at least ever...

Page 16: ...e manually returned to the OFF position When unattended the control light will automatically default to the AMBIENT blue illuminated mode after a short period To dispense boiling water Touch the selec...

Page 17: ...mode was just disabled the safety and select lights will alternatively flash red By default the sleep mode setting is disabled Red boiling water light Continually illuminated This indicates that the b...

Page 18: ...as shown in the adjacent diagram The integral safety lock cannot be disabled Indicator light Safety button To dispense mixed hot and cold water The mixer tap lever is operated as a conventional flick...

Page 19: ...t Warning Lights If there is a fault with the system both the safety light and the warning light will flash for 1 2 second ON and 1 2 second OFF until the fault is rectified Call Zip on 0345 6 005 005...

Page 20: ...Water supply not connected Check to ensure plumbing connection is made Power supply not connected Check power plug is correctly fitted and switch is turned on Water or moisture on the tap control Eli...

Page 21: ...wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for collection...

Page 22: ...uthorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary a...

Page 23: ...23 INSTALLATION INSTRUCTIONS USER MANUAL 804428UK V1 03 OCT 2017 ZIP EP HYDROTAP TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK NOTES...

Page 24: ...428UK V1 03 OCT 2017 ZIP EP HYDROTAP TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005 s...

Reviews: