SECTION 2 FILTER & TAP INSTALLATION

• 

Ensure that the mains cold water supply is 

turned off.

• 

Choose a suitable location, (cupboard back or 

side wall).  

• 

Mount the filter head in an upright position, 

using the screws supplied in the fittings kit.

• 

Ensure there is enough headroom for the 

filter cartridge to be easily fitted and removed. 

*Allow a min. 80mm base clearance.

• 

Attach the pipes as model installation  

diagram (see section 3), noting the flow 

directions as marked on the filter head and 

non return valve (see sections 3).

*Min. 80mm

Clearance to 

cabinet floor.

2.3 Filter installation 

(see individual model arrangements pages 13-14)

Inlet

Outlet

Rotate

Insert

2.2 Mounting the filter head

Flow

Flow

Scale filter 

Sub micron filter 

Flow

Tee piece, stop 

cock and flush line 

(supplied)

2.1 Installing the filter system

• 

The ¼” pipe supplied must be carefully measured and cut to allow for the connection 

of the filter,valves and Command Centre.

• 

Flush water through the supply line thoroughly before connection

• 

Connect the pressure limiting valve to the isolating valve (not supplied). 

• 

Mount the filter head and connect the stop cock in a convenient position.

• 

Connect the filter assembly plumbing between the pressure limiting valve and the 

inlet of the Command Centre, using the ¼” tubes supplied. (ensure that the non 

return valve is fitted) (see individual model arrangements pages 13-14).

• 

Note the flow direction, arrowed on the top of the filter head & non return valve.

• 

Ensure the flush stop cock is accessible after installation, this is required to flush 

water through the filter, when the filter is installed or changed.

•  Write the date of replacement on the new filter cartridge label. 
•  Remove the protective plastic cap from the filter cartridge, lubricate 

o-rings with 

water. (Do not use any petroleum products to lubricate the o-rings).

•  Align the tabs of the cartridge with the filter head and insert it up into the filter head.
• 

Turn the cartridge a quarter turn anti-clockwise until it stops and locks into position.

Note

 Read and undertake in conjunction with the Command Centre

 

installation, see Section 3.

 

The external filter is a sub-micron scale filter designed to reduce scale build up in the tank, which also includes a 

carbon block to improve taste and odour.

Summary of Contents for HYDROTAP 2500UK

Page 1: ...AL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK ZIP HYDROTAP INSTALLATION INSTRUCTIONS USER MANUAL MODEL NUMBER 2500UK 2501UK Filtered boiling and ambient drinking w...

Page 2: ...5 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK The HydroTap series offers a range of interchangeable taps to suit the customer s needs Arc range Celsius Arc range These standalone ta...

Page 3: ...arrangements Step 2 Check for adequate ventilation Section 1 Ventilation 1 1 Ventilation for all models 10 Step 3 Install the filter tap Section 2 Filter system tap installation 2 1 Installing the fi...

Page 4: ...o a wholesome water supply Check the Command Centre rating plate and ensure correct power is available Check the under counter cupboard floor supporting the Command Centre is adequate for its total we...

Page 5: ...ap mounted on a sink or worktop which has been designed for residential applications The HydroTap utilises an immersion heating element to boil the water These boiling models will dispense boiling wat...

Page 6: ...led using the font ensure the tap body is located so the tap outlet vent safely dispense into the sink bowl area Lifting Take care when lifting The Command Centre may exceed safe lifting limits If you...

Page 7: ...water jets Do not expose the Zip HydroTap to the elements of nature Due to the process of continuous improvement Zip reserves the right to change details mentioned in this manual without notice Visit...

Page 8: ...ered Boiling 1 8 1x13A 1 50 216 x 272 x 338 6 5 Min Max water supply pressure Arc and Cube HydroTaps 0 17 MPa 1 7 bar 0 5 MPa 5 0 bar Celsius mixer taps 0 17 MPa 1 7 bar 0 5 MPa 5 0 bar Filter 0 17 MP...

Page 9: ...required The Command Centre must be installed in accordance with IEE regulations See Technical specification page 8 for power ratings Note Check all cable and hose lengths against inlet outlet positio...

Page 10: ...ated in the specification sheets and installation instructions must be observed Adequate ventilation must be provided to ensure that the cupboard space temperature does not exceed 350 C 1 2 Preferred...

Page 11: ...ter through the supply line thoroughly before connection Connect the pressure limiting valve to the isolating valve not supplied Mount the filter head and connect the stop cock in a convenient positio...

Page 12: ...tic pipe and connect it to the ambient outlet located on the top of the Command Centre ambient models only Measure and trim the CLEAR silicone tube and connect it to the vent outlet located on the top...

Page 13: ...ET RED CLEAR BLUE AMBIENT OUTLET BLUE Note Electrical power cable length is 3 0m Position the Command Centreaccording to the hose and cable lengths supplied Note All silicon tubes plastic pipes to the...

Page 14: ...m 50mm 535mm Note Electrical power cable length is 3 0m Position the Command Centreaccording to the hose and cable lengths supplied Note All silicon tubes plastic pipes to the taps must be cut to size...

Page 15: ...ck the water is clear with no soapy looking bubbles from the residue of the factory sanitisation process 4 3 Filter replacement For safe operation the filter cartridge should be replaced at least ever...

Page 16: ...e manually returned to the OFF position When unattended the control light will automatically default to the AMBIENT blue illuminated mode after a short period To dispense boiling water Touch the selec...

Page 17: ...mode was just disabled the safety and select lights will alternatively flash red By default the sleep mode setting is disabled Red boiling water light Continually illuminated This indicates that the b...

Page 18: ...as shown in the adjacent diagram The integral safety lock cannot be disabled Indicator light Safety button To dispense mixed hot and cold water The mixer tap lever is operated as a conventional flick...

Page 19: ...t Warning Lights If there is a fault with the system both the safety light and the warning light will flash for 1 2 second ON and 1 2 second OFF until the fault is rectified Call Zip on 0345 6 005 005...

Page 20: ...Water supply not connected Check to ensure plumbing connection is made Power supply not connected Check power plug is correctly fitted and switch is turned on Water or moisture on the tap control Eli...

Page 21: ...wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for collection...

Page 22: ...uthorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary a...

Page 23: ...23 INSTALLATION INSTRUCTIONS USER MANUAL 804428UK V1 03 OCT 2017 ZIP EP HYDROTAP TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK NOTES...

Page 24: ...428UK V1 03 OCT 2017 ZIP EP HYDROTAP TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005 s...

Reviews: