Page26 INSTRUCTION MANUAL CENTRAL COMMAND STATIONS MX10, MX10EC
8.2
Voltage & Current Setting
Screen in normal operation
BLUE
if the rotary knob is turned fast,
it changes to voltage & current setting screen.
This means:
VOLT & AMPERE MAIN (main settings)
YELLOW
APPLICATION:
Scrolling with the rotary knob: set cursor (
) to the value that shall be changed.
Press rotary knob
marked (
) value is framed, you can now change the value.
Change the value with the rotary knob and adjust it according to your wishes.
in case of voltage: immediately effective on the track output.
in case of current limit: Shows threshold, measured value is shown again later.
Press rotary knob
adjusted value is stored, the rotary knob now scrolls again.
RETURNING to normal operation or to menu:
Press
BUTTON
3
(
)
to normal screen
BLUE
or
Position cursor
(
)
on “EXIT” and press rotary knob
Timeout
after 3 seconds without operation
normal screen
or
Press
button 2 (MENU)
to the menu screen
GREY
Proceed (from the main settings) to the detailed settings:
Press
BUTTON
1
(
)
to voltage & current detail screen
YELLOW
VOLT & AMPERE DETAIL (detailed setting)
This
YELLOW
configuration screen can also be accessed
via the menu-line VOLT & AMPERE DETAIL (see 8.8)
The “detailed setting” provides a number of parameters
surpassing the “main settings” for a perfect adjustment of
the individual needs.
Each of the values is displayed and has to be adjusted
individually for track 1 and 2 . Those lines are marked by
1:
and
2:
Additionally: for addressing and programming procedures
in service mode on track 2 (i.e. track 2 as programming
track) there are the lines
SERV:
and for updates and
sound loading processes the lines
UPD:
In many cases the default values can be used, especially
if the potential capacity of the device is not fully used.
APPLICATION:
Scrolling with the rotary knob: Set cursor (
) to the parameter which shall be configured.
On the screen only two or three lines are visible at the same time.
Press rotary knob
marked (
) value is framed, you can now change the value.
Adjust the tagged value with the rotary knob according to your wishes.
Press
Button
3
(
) (instead of rotary knob)
undo erroneous adjustment.
Press rotary knob
adjusted value is stored.
RETURN to normal operation:
Press
BUTTON
3
(
)
to normal screen
BLUE
NOTE: The configurations in “main settings” corre-
spond to the points “running voltage” and ”OVC
threshold” in the “detailed setting” (see description be-
low). This display can also be reached via the MX10
menu (chapter 8.8).
NOTE: During addressing and programming proce-
dures in service mode on track 2, the values adjusted
in “2” change to the values defined in “SERV”; the
same is valid for updating procedures. This can either
mean a rise or a lowering of the track voltage.
Running voltage
track 1 - upper value
track 2 - lower value
Current threshold OVC
track 1 - upper value
track 2 - lower value