Output A1 and A2: 0 - 10 V
Output A3: 0 - 10 V
I
max
per 6 mA (short-circuit-proof)
I
max
per 10 mA (short-circuit-proof)
Max. contact rating of the internal relay 2 A / 250 V AC
Max. permissible ambient temperature
for operation
55
°
C
Min. permissible ambient temperature 0
°
C (if mains voltage is not switched off up to -20
°
C)
Permissible installation height
0...4000 m amsl
≤
1000 m: no limitation
> 1000 m: max. permissible output current = current indication name plate minus 5 % /
1000 m
> 2000 m: max. permissible line voltage = max. voltage indication name plate minus
1.29 % / 100 m
Permissible rel. humidity
85 % no condensation
Electromagnetic compatibility for the
standard voltage 230 / 400 V accord-
ing to DIN IEC 60038
Interference emission EN 61000-6-3 (domestic household applications)
Interference immunity EN 61000-6-2 (industrial applications)
Harmonics current
Active power factor adjustment for sinusoidal input current (PFC = Power Factor
controller), harmonic current in accordance with EN 61000-3-2 are guaranteed
Vibratory strength
(for vertical installation, i.e. cable inlet
down).
Broadband noise (simulated life-endurance test) in accordance with EN 61373, cat-
egory 1 class B.
Shock test according to EN 61373, category 1
Housing protection
IP54
*
Regarding the mains connection, the Fcontrol devices are to be classi
fi
ed as category
“
C2
”
devices according to the relevant
DIN EN 61800-3. The increased requirements placed on electrical interference > 2 kHz for category
“
C1
”
devices are
complied with in addition.
12.1.1
Performance reduction during elevated ambient temperatures
The maximum permissible temperature for the rated current at rated voltage is speci
fi
ed as rated
temperature.
Since the dissipation of the power loss (heat development) in the device is decisively dependent on
the ambient temperature, the max. load must be reduced at an ambient temperature above the rated
temperature (
following table)!
The average value measured during a 24 h period must be 5 K under the max. ambient temperature.
For installation in a switch cabinet, the device
’
s dissipation and its possible affect on the ambient
temperature must be taken into consideration!
Maximal motor current depending on ambient temperature
Type
35
°
C
40
°
C
45
°
C
50
°
C
55
°
C
[A]
[A]
[A]
[A]
[A]
FTET4AHMQ-L
4
3.5
3.0
2.0
1.6
FTET6AHMQ-L
6
6.0
5.5
4.5
4.0
FTET10AHMQ-L
10
10.0
10.0
10.0
9.0
Operating Instructions
Fcontrol
–
model series FTET4/6/10AHMQ-L
Enclosure
L-BAL-E139-GB 2022/03 Index 006
Part.-No.