heating in stall washing operation
Wash setpoint
Washing Temperature
The heating setpoint of the stall is set to 15.0
°
C in wash mode at the factory.
This value becomes active when the device is in the wash mode.
setting range: 0.0..70.0
°
C
Factory setting: 15.0
°
C
Shutter preheat operation
Washing Kl-max.
Washing Kl-max.
The shutter is fully opened (100%) in washing operation in the factory setting. The
shutter opening can be limited if required.
Setting range: 0...100 %
Factory setting: 100 %
Heating in preheat operation
Preheat setpoint
Preheat setpoint
This value becomes active when the device is in the heat mode (D1 function =
|
2D
|
and D3 function =
|
3D
|
for operation with external switch, switch position 2).
setting range: 0.0..70.0
°
C
Factorysetting: 0.0...20.0
°
C
7.13.4
External switch extension
For Stall ON/OFF, Stall preheat, Stall washing
With the appropriate programming an external 3-step switch can be connected at the digital inputs D1
and D3
In this way a special wash mode and heat mode can be activated in addition to stall ON / OFF.
Necessary Settings
•
D1 function =
|
2D
|
•
D2 function =
|
2D
|
S1
S2
S3
Mode
0
0
0
Stall off
1
0
0
Stall on
0
1
0
Cot Preheating
0
0
1
Cot Washing
0
switche opened
1
switches closed
Operating Instructions
Fcontrol
–
model series FTET4/6/10AHMQ-L
The Installation menu
L-BAL-E139-GB 2022/03 Index 006
Part.-No.
43/92