Parameter
Factory set-
ting
Cot 1
Cot 2
Cot 3
Cot 4
Cot 5
Information
Heating2
H2 Mode
OFF
Temperature source for H1 and/or
H2
|
0
|
= E1
|
1
|
= E2
|
2
|
= Bus
|
3
|
= E3
Mode for H2
|
OFF
|
|
1
|
= Relays
|
2
|
= 0...10 V
|
3
|
= piglet nest heating
|
4
|
= piglet nest heating (Blaffert
only P-controller)
H2 Input
0
H2 Val<Set=+
ON
Blaffertconst.
2.9
H2 KP
100 %
H2 KI
1 %
H2 KD
100 %
H2 TI
5 %
Setp. Derating
Increase
0.2 K/h
Derating
0.1 K/h
Max. Rising
5.0 K
Minimum extra
50 %
Sensor adjust
Adjustment E1
0.0 K
Adjustment E2
0.0 K
E3
0.0 K
Heatexchange
WT Mode
OFF
Bypass start
75 %
Bypass 100 %
100 %
Freshair start
0 %
Freshair 100 %
75 %
Freshair max.
100 %
Inlet air off
70 %
Offstate temp.
18.0
°
C
Off on group
1
Freshairshutter
ZK Mode
OFF
Freshair linear
OFF
FAS Start
75 %
ZK 100 %
90 %
Changeover temp.
10.0
°
C
FA min-HE off
OFF
Exhaust system
Exhaust mode
OFF
Exhaust mode
|
OFF
|
|
1
|
= group, relation to central ex-
haust air total
|
2
|
= group, relation to stall ventila-
tion
Group variants
|
OFF
|
|
1
|
= two regulated of equal size
|
2
|
= switch on by relay max. 4
groups
|
3
|
= two regulated of different size
Exhaust min.
10 %
Group version
OFF
Group count
2
Group1 100%
45 %
Off group2
45 %
On group2
50 %
Minimum2
30 %
Off group3
100 %
On group3
100 %
Minimum3
40 %
Operating Instructions
Fcontrol
–
model series FTET4/6/10AHMQ-L
Menu tables
L-BAL-E139-GB 2022/03 Index 006
Part.-No.
76/92