64
8. Quick charging is forbidden except in emergency.
9. During quick charging, the battery must be removed from the motorcycle first and then be
charged.
10. While battery is exchanged, please do not use liquid-feeding battery.
11. A voltmeter shall be employed to check the state of charged battery.
Service Data
Item
Specification
Battery
Capacity/type
12V-9AH/ dry-charged type
Voltage
(
20
℃
)
Fully charged
13.1V
Must be charged
12.3V(stop working for one hour)
Charging current
Standard
:
0.9A
,
Quick
:
9A
Charging time
Standard
:
10-15hours; Quick
:
30minutes
Magneto
Capacity
100W/8000rpm
Coiling impedance value
(
20
℃
)
White-white 0.5-10Ω
Voltage
regulator
Type
Full-wave rectification
Battery charging voltage
14.5V±0.4V/5.000rpm
Tightening torque Tools
Rectifier bolt 5.0 N·m
Universal non-adjustable
spanner
High-voltage coil pinch bolt 9.0 N·m Flywheel remover
Flywheel locknut 5.0 N·m Testing device
Vehicle block protecting plate bolt 9.0 N·m Multimeter
1.2 Fault Diagnosis
No power Unstable power
Battery over discharged Wiring of battery is poorly contacted.
Wiring of battery is not connected. Discharging system is of poor contact.
Fuse fails. Lighting system is of poor contact or short circuit.
Power switch is poorly contacted.
Low voltage Poor charging system
Battery is poorly charged. Wire connector is of poor contact, short circuit or
short line.
Poor contact. Defective voltage and current regulator
Poor charging system. Magneto does not work well.
Poor voltage and current regulator
Summary of Contents for RKV 200
Page 1: ...1 RKV 200 Motorcycle Service Manual...
Page 18: ...18...
Page 44: ...44 Symptom Electric horn mutes Diagnosis procedures...
Page 143: ...143...
Page 144: ...144...
Page 158: ...158 Gearshift drum Shifting fork Shift rail Principal shaft assembly Vice shaft assembly...
Page 171: ...171 Complete QJ200 2A Schematic Circuit Diagram...