If you do not succeed in starting the engine
Ignition system failure signalization
*Coolant heater
Return the key to '0' position. Wait 60 second and repeat
the start.
Never help the stopping engine by a starter.
You are being exposed to the danger of starter
damage.
C15N127
A failure of the glowing system is indicated by flashing of
the glowing signal lamp (3) and simultaneous activation of
the red (1) or orange (2) signal lamp. The failure code is
displayed in the screen.
- If the engine is at standstill, the glowing signal lamp
flashes once a second and the signal lamp (2) glows,
glowing in the emergency mode is performed similarly as
at low temperatures regardless the temperature of the
cooling liquid.
- If the engine is at standstill, the glowing signal lamp
flashes twice a second and the signal lamp (2) glows, the
glowing is turned off (not functioning).
- If the engine is running, the glowing signal lamp glows
permanently and the signal lamp (1) glows, there is
a failure of the glowing control and glowing was not
finished. The failure must be immediately eliminated since
there is a danger that the accumulator will be discharged.
P18N056
Is mounted on the right side of engine block.
output 1,000 W
voltage 230 V
C209
DRIVING OPERATION
86
Summary of Contents for FORTERRA HSX Series
Page 1: ...FORTERRA HSX 120 130 Tractor is Zetor Since 1946 140 120 130 140 OPERATOR S MANUAL 2 2018...
Page 3: ...2...
Page 51: ...NOTES 50...
Page 75: ...NOTES 74...
Page 115: ...NOTES 114...
Page 139: ...NOTES 138...
Page 153: ...NOTES 152...
Page 168: ...167...
Page 169: ...Fuse panel B FHSX18N001 ELECTRIC INSTALLATION 168...
Page 220: ...219...