ZHDN 2500-150
56
Specifications
www.zepro.com
Image 63. Calculation of minimum conductor cross sectional area
ZHDN 2500 (200 bar)
Hydraulic unit 7100
12 volt
24 volt
Pump - Motor unit
245 A
145 A
Magnet (hydraulic unit)
4.2 A
2.1 A
Magnet (electric safety valve)
1.5 A
0.75 A
Solenoid
1.8 A
0.9 A
Minimum recommended conductor cross sectional area
(copper cables, plus and minus cables)
Control cable
1.5 mm
2
1.5 mm
2
Supply cable, L < 8m
35 mm
2
35 mm
2
Supply cable, L = 8 - 15m
50 mm
2
35 mm
2
Supply cable, L > 15m
-
50 mm
2
Battery
Min. capacity, I
min
180 Ah
170 Ah
Min. voltage during operation, U
min
(at lift)
9 V
18 V
-
+
-
+
L
L
U
min
I
min
I
min
U
min
14.3
Maximum power consumption - Minimum recommended conductor cross
sectional area