![Zepro ZHDN 2500-150 Installation Instructions Manual Download Page 37](http://html1.mh-extra.com/html/zepro/zhdn-2500-150/zhdn-2500-150_installation-instructions-manual_931520037.webp)
ZHDN 2500-150
Connection unit
37
www.zepro.com
9.1.1
Information codes
Codes are shown on the display in a sequence. First a letter for identification of information, fol
-
lowed by figures or segments for further information and then ending with a pause:
When the CS (cabin switch) is switched on, the current program configuration (P) is displayed
first, followed by configuration number.
The number of volts detected is then displayed and, after
this, the current software version (J), followed by version number.
As long as no control device is used, a scrolling sequence is then displayed, with sensor indication
(C), followed by 0-6 segments showing which sensors have a signal.
When a control device is used, the control device being used (1-7) is displayed, followed by which
button has been pressed, segments B, C, E or X (X symbolises the 4th button on the respective
control device (2h1 for fixed control device 1, 2h2 for fixed control device 2, lock knob for radio
control device and coil control device).
The control devices are symbolised by the figures 1-7.
1. Fixed control device 1, including two-hand button 2h1
2. Fixed control device 2, including two-hand button 2h2
3. Radio control device, External
4. Coil control device
5. Truck slider control device
6. Radio control device, internal module
7. CS (cabin switch)
Once a button has been released, the control system for the current control device is locked for
a while to ensure that no other person operates the lift from another control device. During the
period the control system is locked for the current control device, its number (1-7) will flash on
the display. This primarily applies to radio and coil control devices as control devices have such a
short locking period that there is hardly time to see the indication.
Coil and radio control devices can be equipped with a locking function. Once the control device has
been used, the control system is locked for the current control device until it is unlocked manually
from the respective control device's deactivation button. With some configurations, however, the
coil control device can, for safety reasons, always tilt the platform down in the event of the opera-
tor getting shut inside.