Connection unit
www.zepro.com
Information codes
Identification
Code 1 Code
2
Code
3
Information
Other
P
(Program
configuration)
00–99
Cancelled configuration
-
Dividers
12/24
Number of volts detected
J
Software version
01–99
Version number
1.-7 (Fixed light)
Active control device
while operating
1-7
Fixed light (1-7) displays active control
device during operation.
B
C
E
X
In
Out
Segment
B, C, E
or X.
Segments B, C, E or X are illuminated
depending on which button is pressed
1-7 (Flashing)
The control device
that the control sys-
tem is locked for for
a while after opera-
tion completed.
1-7
Control device the control system is
locked for.
This primarily applies to radio and coil
control devices as other control devices
have such a short locking period that there
is no time to see the indication.
The number will stop flashing when one
of the current control device's buttons are
pressed.
If the control card has been without voltage
and receives the voltage again when the CS
(cabin switch) is switched on, "7" will flash
on the display and the control card is locked
until the Off/On on the CS is operated.
C
Sensor indication
Segment
1-6 segments indicate sensors.
On - signal in.
Off -no signal in.
(See electrical and hydraulics diagrams
for information about the location of the
sensors).
Di1
Di3
Di6
Di4
Di2
Di5
Example of sequence of information codes:
Program configuration: 01, Voltage detected: 12V, Software version: 02