Z 2500-130/150
48
Functional description Z 2500 MA Autotilt (standard)
www.zepro.com
10
Functional description Z 2500 MA Autotilt (standard)
10.1
Sensors/Inputs
Name
Position
(standard)
Function
Description
Ai 1
Platform
Inclinometer
Measures the platform angle to earth's gravity
Ai 2
Not used in this configuration
B
Controller
Up button
E
Controller
Down button
C
Controller
Tilt button
Used in combination with B and E for tilt up and tilt down
2H
Controller
Two-hand but-
ton
Activated in connection with opening and closing of vehicle
body. Used for quick opening.
Di1
1st boom
Angle sensor
For Autotilt, safety function
Di2
Not used in this configuration
Di3
Not used in this configuration
Di4
Tilting cylinder
Open platform
alarm
Pressure switch for falling pressure connected to +side of
tilting cylinder. In its actuated state, returns the connection
signal (+) to Di4, resulting in output signal (-) at Pa-. At the
same time (+) signal is sent on Pa+. 60 Bar (NC).
Di5
Lift cylinder
Pressure switch For autotilt. 5 Bar (NC).
Di6
Not used in this configuration
Cs
Cab
Activation
No signal in at Cs results in blocked control device terminals.
Signal to Cs usually comes from the cab switch. In individual
cases, where the cab switch is not used, the (+) signal
coming in to Cs is jumpered from (CS PWR) on nearby
terminal.
See also the electrical diagram
: "9.1 Z2500-130/150 MA with electrical autotilt" on
page 41.
Summary of Contents for Z 2500-130 DA
Page 2: ......
Page 77: ...Z 2500 130 150 Specifications 77 www zepro com Image 92 Loading diagram 18 4 Loading diagram...
Page 79: ......