Z 2500-130/150
Installation
19
www.zepro.com
6.2
Control power cable
See also the vehicle manufacturer’s electrical
instructions.
NOTE.
1. If the control power cable is not pre-routed, e.g.
VDHH, route the control power cable from the
driver’s cabin to the lift.
The cable must be protected with rubber grommets
when it passes through beams or walls. If there are
quick connectors, make sure they are effectively
protected from moisture and dirt.
NOTE.
2. Connect the control power cable to the cabin switch
(CS) on the vehicle instrument panel. Connect to
the on-board electrical system via a 10 A (24 V),
15 A (12 V) fuse according the customer’s wishes.
See the connection diagram "9.5 Lift without incli-
nometer" on page 45.
Image 18. Quick connectors must be well protected