Z 2500-130/150
36
Installation
www.zepro.com
6.14
Purging the cylinders
Fully lower the platform a few times. You may have to lift the truck to fully lower the platform.
The tilt cylinders can be purged by raising the platform fully against the vehicle body and then tilting all the way
down.
6.15
Transport lock
Electric hose breakage valves serve as locks for the platform. The lock opens automatically if the down func-
tion is actuated from the control device. The valves are non-return valves that let fluid in from the cylinders but
not out before they are actuated by the flow from the lowering valve. The platform is thus hydraulically locked
during transport.
Summary of Contents for Z 2500-130 DA
Page 2: ......
Page 77: ...Z 2500 130 150 Specifications 77 www zepro com Image 92 Loading diagram 18 4 Loading diagram...
Page 79: ......