First Module Row, Continued
Drop In Remaining Modules In First Row
Place the second module on Tongue side of
first-column Cam Feet and Interlocks.
Align module with Interlock tim-
ing marks. Allow 1/2” gap
between modules.
1/2”
i
ii
6c
Tol/- 1/4”
Insert Cam Feet at
rear of remaining first-
row modules.
iii
Ensure Gaps Between Modules Are Consistent on Both Sides
6d
Gap between modules should be consistent at the
upper and lower edge of each module.
If module gap is not even, detach Cam Foot base and
and re-seat modules until row is straight.
Correct