ZS SPAN INSTALLATION MANUAL FOR RAIL-BASED APPLICATIONS - U.S.
6.4 Hybrid Interlocks
NOTE:
The non-bonding Hybrid Interlock does not create a bonding path
across modules. An array containing an unbroken row or column of
Hybrid Interlocks requires a Ground Zep on both sides of the break. (A
bonding version of the Hybrid Interlock is available in selected regions,
and the bonding Hybrid Interlock does create a bonding path across
modules.)
3 holes can receive Cam Foot threaded
stud
In the event that a
module must be removed
for servicing, the Rockit
can be removed from
Hybrid Interlock using
#30 Torx Bit in set screw.
Level using #30 Torx
Bit in hole receiving
Cam Foot base
A Cam Foot-Interlock conflict occurs when the location
of a Cam Foot coincides with the location of an
Interlock.
The Hybrid Interlock has a dual function: attachment
to the Comp Mount and structural connection between
modules.
!