© 2013/EN Zep Solar, Inc. reserves the right to make specifications changes without any prior notice. All rights reserved.
www.zepsolar.com
Document #800-0329-001 Rev F
File Generated July 3, 2013
Page 25
ZS SPAN INSTALLATION MANUAL FOR RAIL-BASED APPLICATIONS - U.S.
4.2.5 Single Module Installation
A standalone module requires two Cam Feet per supporting frame side, for a total of 4 Cam Feet.
This remains true regardless of module orientation or drop-in direction.
Figure 4.7 Standalone Module Installation
4.3 Grounding/Earthing
The Zep Compatible design concept allows the installer to build a hyper-bonded array up to a
specified size with a single ground bond connection (an Equipment Grounding Conductor). In a
hyper-bonded array, every module is structurally and electrically bonded to the surrounding mod-
ules, on all sides. The rotation of the Key side into the Zep Groove, and the dropping in of the next
row of PV modules onto the Tongue side, acts to establish an electrical bond for all UL listed com-
ponents by cutting through the anodization on the Zep Groove. This eliminates the need for exten-
sive lengths of copper wire run to every module in order to ground the array.
In some situations, portions of the array may require additional bonding connections. The illustra-
tions on the following pages show when additional Equipment Ground Conductors or jumpers are
required.
Portrait
Cam Foot
Landscape
East-West
North-South
Drop-in
direction
Drop-in
direction