© 2013/EN Zep Solar, Inc. reserves the right to make specifications changes without any prior notice. All rights reserved.
www.zepsolar.com
Document #800-0329-001 Rev F
File Generated July 3, 2013
Page 68
ZS SPAN INSTALLATION MANUAL FOR RAIL-BASED APPLICATIONS - U.S.
.
6.2.5 Pest and Debris Control
In regions where nesting animals and birds are a concern, additional mesh can be attached either
to the Array Skirt or directly to the Zep Groove of the module frames. Mesh can also be used as a
screen to prevent rooftop debris from collecting underneath the array. Contact Zep Solar Support
for more information.
6.3 Removing the First-Row Array Skirt
Follow these steps to remove the Array Skirt subsequent to module installation.
1.
Slide Grips off the first-row Cam Feet using a flat screwdriver.
Inside Corner Cap
Part No. 850-1425
Apply screwdriver to one
side of position notch for
leverage.
Slide in
Slide out