Figure 17.
Water - Channel x - Total register
Volume Value After Download
[
Keep Current Value /
Set Value
]: sets the
initial value of the total register of
water
after an ETS download. When selecting
“Set value”, an additional textbox appears to enter the desired value for
Consumed water
, in terms of the selected measurement units.
Sending Mode for Volume
[
Disabled
/ Periodic / With Value Change / Periodic
and with Value Change
]: analogous to the same parameter of the
“Configuration” tab (see section 2.3.1) applied to the total register of the water
channel being configured.
The communication object
“[Water][Chx][RT] Consumed Water”
will always be visible
when the channel is enabled. This object will store the accumulated value of the
consumed water of the corresponding channel. It can only be initialized by writing on it
the desired energy value.
2.3.2.2
PARTIAL REGISTERS
Up to 2 partial registers can be enabled to store the volume values of each channel
during a period of time (for example, a day, a month …).
Two binary objects “
Reset Partial Registers 1
” and “
Reset Partial Registers 2
” are
available to reset a partial register anytime (set to zero). Moreover, a
periodic reset
can
be configured by parameter (see section 2.1.2).
Each time a partial register is restarted, the reset date is stored in
“Starting Date Partial
Registers n
”
and the values of the partial register are sent to the bus.
Note:
Partial registers are disabled by default. Please refer to section 2.3.1 for enabling
them.