IDAC
Technical Support:
21
Please refer to the specific manual “
Brightness
” (available in the IDAC
product section at the Zennio website,
) for detailed
information about the functionality and the configuration of the related
parameters
Note
:
This parameter will only be available if Doorbell Button is enabled in
the "Configuration" tab of the Outdoor Module, and additionally the option
selected for the LED State parameter is "On"
.
2.3.4
DOORBELL BUTTON
The Outdoor Module has single button with doorbell functionality. This button type can
be configured as:
Switch Control:
whenever the user touches the button, a binary value will be
sent to the KNX bus. This value is configurable and may be 0 or 1, or
alternate with every touch according to the sequence 1
0
1
…
Hold & Release Control:
as soon as the user touches the button, a binary
value will be sent to the KNX bus. And as long as the user releases the
button, another value will be sent through the same object.
ETS PARAMETERIZATION
When the function
Doorbell Buttons
in “Configuration” tab, in Outdoor Module, a new
tab will be available in the left tree.
Figure 10.
Doorbell Button
Function
[
Switch
/ Hold & Release
]: sets the desired function for the button: