Page – 42/139
AFFZP0BB – ACE3 – User Manual
PARAMETER CHANGE
Parameter
Allowable range
Description
DECEL. BRAKING
(T, TM, CO)
0.1 s ÷ 25.5 s
(by steps of 0.1 s)
This parameter defines the deceleration ramp performed when the
accelerator is released but not completely, i.e. the time needed to
decelerate the motor from 100 Hz down to 0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 8.5).
PEDAL BRAKING
(T, TM, CO)
0.1 s ÷ 25.5 s
(by steps of 0.1 s)
This parameter defines the deceleration ramp performed when the
braking pedal is pressed, i.e. the time needed to decelerate the
motor from 100 Hz down to 0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 8.5).
SPEED LIMIT BRK.
(T, TM)
0.1 s ÷ 25.5 s
(by steps of 0.1 s)
This parameter defines the deceleration ramp performed upon a
speed-reduction request, i.e. the time needed to decelerate the
motor from 100 Hz down to 0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 8.5).
STEER BRAKING
(T, TM)
0.1 s ÷ 25.5 s
(by steps of 0.1 s)
This parameter defines the deceleration ramp related to the
steering angle, i.e. the time needed to decelerate the motor from
100 Hz down to 0 Hz.
A special software feature manages the deceleration ramp
depending on the starting speed (see paragraph 8.5).
MAX SPEED FORW
(T, TM)
0% ÷ 100%
(by 1% steps)
This parameter defines the maximum speed in forward direction
as a percentage of TOP MAX SPEED.
MAX SPEED BACK
(T, TM)
0% ÷ 100%
(by 1% steps)
This parameter defines the maximum speed in backward direction
as a percentage of TOP MAX SPEED.
MAX SPEED LIFT
(P)
0% ÷ 100%
(by 1% steps)
This parameter defines the maximum speed of the pump motor
during lift, as a percentage of the maximum voltage applied to the
pump motor.
1ST PUMP SPEED
(P)
0% ÷ 100%
(by 1% steps)
This parameter defines the speed of the pump motor when 1
st
speed is requested. It represents a percentage of the maximum
pump speed.
2ND PUMP SPEED
(P)
0% ÷ 100%
(by 1% steps)
This parameter defines the speed of the pump motor when 2
nd
speed is requested. It represents a percentage of the maximum
pump speed.
3RD PUMP SPEED
(P)
0% ÷ 100%
(by 1% steps)
This parameter defines the speed of the pump motor when 3
rd
speed is requested. It represents a percentage of the maximum
pump speed.
4TH PUMP SPEED
(P)
0% ÷ 100%
(by 1% steps)
This parameter defines the speed of the pump motor when 4
th
speed is requested. It represents a percentage of the maximum
pump speed.
5TH PUMP SPEED
(P)
0% ÷ 100%
(by 1% steps)
This parameter defines the speed of the pump motor when 5
th
speed is requested. It represents a percentage of the maximum
pump speed.
Summary of Contents for ACE3
Page 14: ...Page 14 139 AFFZP0BB ACE3 User Manual 3 2 Connection drawing ACE3 Traction Standard...
Page 15: ...AFFZP0BB ACE3 User Manual Page 15 139 3 3 Connection drawing ACE3 Traction Premium...
Page 16: ...Page 16 139 AFFZP0BB ACE3 User Manual 3 4 Connection drawing ACE3 Pump Standard...
Page 17: ...AFFZP0BB ACE3 User Manual Page 17 139 3 5 Connection drawing ACE3 Pump Premium...