Troubleshooting
-
Replace the controller.
43)
VDC OFF SHORTED
Cause
The logic board measures a key voltage value that is constantly out of range,
above the maximum allowed value.
Troubleshooting
-
Check that the battery has the same nominal voltage of the inverter.
-
Check the battery voltage, if it is out of range replace the battery.
-
In case the problem is not solved, replace the logic board.
44)
VKEY OFF SHORTED
Cause
The logic board measures a key voltage that is constantly out of range, below
the minimum allowed value.
Troubleshooting
-
Check that the battery has the same nominal voltage of the inverter.
-
Check the battery voltage, if it is out of range replace the battery.
-
In case the problem is not solved, replace the logic board.
45)
POWERMOS SHORTED
Cause
The DC-link voltage drops to zero when a high-side MOSFET is turned on.
Troubleshooting
-
Check that motor phases are correctly connected.
-
Check that there is no dispersion to ground for every motor phases.
-
In case the problem is not solved, replace the controller.
46)
BUMPER STOP
Cause
The two digital inputs dedicated to the bumper functionality are high at the same
time.
Troubleshooting
-
Turn off one or both inputs dedicated to the bumper functionality;
-
If the alarm occurs even if the inputs are in the rest position, check if the
microswitches are stuck.
-
In case the problem is not solved, replace the logic board.
47)
WRONG SET KEY
Cause
The measured key voltage is not the right one for the inverter.
Summary of Contents for ACE3
Page 14: ...Page 14 139 AFFZP0BB ACE3 User Manual 3 2 Connection drawing ACE3 Traction Standard...
Page 15: ...AFFZP0BB ACE3 User Manual Page 15 139 3 3 Connection drawing ACE3 Traction Premium...
Page 16: ...Page 16 139 AFFZP0BB ACE3 User Manual 3 4 Connection drawing ACE3 Pump Standard...
Page 17: ...AFFZP0BB ACE3 User Manual Page 17 139 3 5 Connection drawing ACE3 Pump Premium...