AFFZP0BB – ACE3 – User Manual
Page – 121/139
Troubleshooting:
-
A travel demand or a pump request cancels the alarm.
-
If the alarm appears at key-on without any CLEAR EEPROM performed,
replace the controller.
3)
EEPROM KO
Cause:
A HW or SW defect of the non-volatile embedded memory storing the controller
parameters. This alarm does not inhibit the machine operations, but it makes
the truck to work with the default values.
Troubleshooting:
Execute a CLEAR EEPROM procedure (refer to the Console manual). Switch
the key off and on to check the result. If the alarm occurs permanently, it is
necessary to replace the controller. If the alarm disappears, the previously
stored parameters will be replaced by the default parameters.
Summary of Contents for ACE3
Page 14: ...Page 14 139 AFFZP0BB ACE3 User Manual 3 2 Connection drawing ACE3 Traction Standard...
Page 15: ...AFFZP0BB ACE3 User Manual Page 15 139 3 3 Connection drawing ACE3 Traction Premium...
Page 16: ...Page 16 139 AFFZP0BB ACE3 User Manual 3 4 Connection drawing ACE3 Pump Standard...
Page 17: ...AFFZP0BB ACE3 User Manual Page 17 139 3 5 Connection drawing ACE3 Pump Premium...