![Zapi ACE2 User Manual Download Page 83](http://html2.mh-extra.com/html/zapi/ace2/ace2_user-manual_3165751083.webp)
AF2ZP0CL - ACE2 - User Manual
Page - 83/85
11) SLIP PROFILE
Cause:
There is an error on the choice of the parameters of the slip profile.
Troubleshooting:
Check in the hardware setting menu the value of those parameter
12) EEPROM KO
Cause:
It’s due to a HW or SW defect of the non-volatile embedded memory
supporting the controller parameters. This alarm does not inhibit the machine
operations, but the truck will work with the default values.
Troubleshooting:
Try to execute a CLEAR EEPROM operation (refer to Console manual).
Switch the key off and on to check the result. If the alarm occurs
permanently, it is necessary to replace the controller. If the alarm disappears,
the previously stored parameters will have been replaced by the default
parameters.
13) FORW+BACK
Cause:
This alarm occurs when both the travel demands (Fwd and Bwd) are active
at the same time.
Troubleshooting:
Check the wiring of the Fwd and Rev travel demand inputs (use the readings
in the TESTER to facilitate the troubleshooting). Check the microswitches for
failures.
A failure in the logic is possible too. So, when you have verified the travel
demand switches are fine working and the wiring is right, it is necessary to
replace the ACE-2 logic board.
Summary of Contents for ACE2
Page 7: ...AF2ZP0CL ACE2 User Manual Page 7 85 2 3Block diagram...
Page 28: ...Page 28 85 AF2ZP0CL ACE2 User Manual 7 3Connection drawing Traction configuration...
Page 29: ...AF2ZP0CL ACE2 User Manual Page 29 85 7 4Connection drawing Pump configuration...
Page 30: ...Page 30 85 AF2ZP0CL ACE2 User Manual 7 5Connection drawing Combi configuration...
Page 33: ...AF2ZP0CL ACE2 User Manual Page 33 85 8 3 2 Pump configuration...