Page - 16/85
AF2ZP0CL - ACE2 - User Manual
Connection of encoder with +12 V power supply.
U
VERY IMPORTANT
It is necessary to specify in the order the type of encoder used, in terms of
power supply, electronic output and n° of pulses for revolution, because
the logic unit must be set in the correct way by Zapi.
4.2.6 Main
contactor and key connection
-
The connection of the main contactor can be carried out following the
drawing in the figure
-
The connection of the battery line switches must be carried out following
ZAPI instructions.
-
If a mechanical battery line switch is installed, it is necessary that the key
supply to the inverter is open together with power battery line; if not, the
inverter may be damaged if the switch is opened during a regenerative
braking.
-
An intrinsic protection is present inside the logic when the voltage on the
battery power connection overtakes 40% more than the battery nominal
voltage or if the key is switched off before the battery power line is
disconnected.
4.2.7 Insulation of truck frame
U
As stated by EN-1175 “Safety of machinery – Industrial truck”, chapter 5.7,
“there shall be no electrical connection to the truck frame”. So the truck
frame has to be isolated from any electrical potential of the truck power
line.
Summary of Contents for ACE2
Page 7: ...AF2ZP0CL ACE2 User Manual Page 7 85 2 3Block diagram...
Page 28: ...Page 28 85 AF2ZP0CL ACE2 User Manual 7 3Connection drawing Traction configuration...
Page 29: ...AF2ZP0CL ACE2 User Manual Page 29 85 7 4Connection drawing Pump configuration...
Page 30: ...Page 30 85 AF2ZP0CL ACE2 User Manual 7 5Connection drawing Combi configuration...
Page 33: ...AF2ZP0CL ACE2 User Manual Page 33 85 8 3 2 Pump configuration...