SUBMENU "SPECIAL ADJUST"
1) ADJUSTMENT#01
Reserved.
2) ADJUSTMENT#02
Reserved.
3) SET
CURRENT
It adjusts the regolation of maximum current. It shouldn’t be changed.
4) HIGH
ADRESS
Reserved.
5) DEBUG
MODE
Reserved.
6) INVERTER
TYPE
It decides what kind of inverter is used.
0 and 1: traction.
2 and 3: pump.
The change of this parameter changes the other parameters at the next
keyoff.
7) SAFETY
IN
0: input allways closed (bridged)
1: safety_in_drived: safety came from a different controller, need a can
handshake.
2: general purpose input (not jet defined. Need hardware change)
8) SAFETY
OUT
0: none : fa comunque la diag all'init per verificare il funzionamento.
1: driver: is for drive a safety in.
2: general purpose: standard function: reverse direction indicator.
9) MAIN
CONTACTOR
OFF
No main contactor (directly connect to +Battery)
ON
Main contactor in stand alone config
OPTION#1
Trpump 1 only MC
OPTION#2
Trpump 2 MC
10) AUX OUT FUNCTION
ON/OFF. If OFF, A18 is not drived and there is no diagnosis on it.
8.4.2 Pump
Using the config menu of the programming console, the user can configure the
following functions.
SUBMENU "SET OPTIONS"
1) DISPLAY
TYPE
This parameter decides wich display is connected to the inverter.
0: No Display
1: MDI PRC connected
2: ECO DISPLAY connected
Summary of Contents for ACE2
Page 7: ...AF2ZP0CL ACE2 User Manual Page 7 85 2 3Block diagram...
Page 28: ...Page 28 85 AF2ZP0CL ACE2 User Manual 7 3Connection drawing Traction configuration...
Page 29: ...AF2ZP0CL ACE2 User Manual Page 29 85 7 4Connection drawing Pump configuration...
Page 30: ...Page 30 85 AF2ZP0CL ACE2 User Manual 7 5Connection drawing Combi configuration...
Page 33: ...AF2ZP0CL ACE2 User Manual Page 33 85 8 3 2 Pump configuration...