account thermal and voltage drop problems.
4
Can advantages:
The complexity of today systems needs more and more data, signal and
information must flow from a node to another. CAN is the solution to different
problems that arise from this complexity
- simplified design (readily available, multi sourced components and tools)
- lower costs (less and smaller cables )
- improved reliability (fewer connections)
- analysis of problems improved (easy connection with a pc to read the data
flowing through the cable).
4.2.4 Wirings: I/O connections
-
After crimping the cable, verify that all strands are entrapped in the wire
barrel.
-
Verify that all the crimped contacts are completely inserted on the connector
cavities.
U
A cable connected to the wrong pin can lead to short circuits and failure;
so, before turning on the truck for the first time, verify with a multimeter the
continuity between the starting point and the end of a signal wire.
-
For information about the mating connector pin assignment see the
paragraph “description of the connectors”.
4.2.5 Connection of the encoder
1) ACE2 card is fit for different types of encoder. To control AC motor with Zapi
inverter, it is necessary to install an incremental encoder with 2 phases
shifted of 90°. The encoder power supply can be +5 or +12 V. It can have
different electronic output.
A8 +5V/+12V positive of encoder power supply.
A15 GND
negative of encoder power supply.
A7 ENC A
phase A of encoder.
A14 ENC B
phase B of encoder.
2) Connection of encoder with +5 V power supply.
Summary of Contents for ACE2
Page 7: ...AF2ZP0CL ACE2 User Manual Page 7 85 2 3Block diagram...
Page 28: ...Page 28 85 AF2ZP0CL ACE2 User Manual 7 3Connection drawing Traction configuration...
Page 29: ...AF2ZP0CL ACE2 User Manual Page 29 85 7 4Connection drawing Pump configuration...
Page 30: ...Page 30 85 AF2ZP0CL ACE2 User Manual 7 5Connection drawing Combi configuration...
Page 33: ...AF2ZP0CL ACE2 User Manual Page 33 85 8 3 2 Pump configuration...