Page - 60/85
AF2ZP0CL - ACE2 - User Manual
16) CUTBACK SWITCH
The level of the Speed Reduction Microswitch.
-
ON / GND = active entry of speed reduction microswitch.
-
OFF / +VB = non active entry of microswitch.
17) HAND BRAKE
The level of the Hand Brake Microswitch.
-
ON / GND = active entry of Brake pedal Microswitch.
-
OFF / +VB = non active entry of microswitch.
18) BRAKEPEDAL POT.
The percentage of the pressure on the brake pedal (100% if the pedal is
totally pressed, 0% if the pedal is released).
19) 2ND HOURMETERS
This parameter displays the working hour of traction controller.
20) STEER ANGLE
It shows the steering angle.
8.9.2 Pump
1) BATTERY
VOLTAGE
Level of battery voltage measured at the input to the key switch.
2) MOTOR
VOLTAGE
This is the voltage supplied to the motor by the inverter; it is expressed as a
percentage of the full voltage (which depends of the battery voltage).
3) VOLTAGE
BOOSTER
This is the booster of the voltage supplied to the motor in load condition; it is
expressed in a percentage of the full voltage.
4) FREQUENCY
This is the frequency of the voltage and current supplied to the motor.
5) ENCODER
This is the speed of the motor, expressed in the same unit of the frequency;
this information comes from the speed sensor.
6) SLIP
VALUE
This is the difference of speed between the rotating field and the shaft of the
motor, expressed in the same unit of the frequency.
7) CURRENT
RMS
Root Mean Square value of the motor current.
8) MOTOR
POWER
It is the power provided to the motor.
9) BATTERY
CHARGE
The percentage Charge level of the battery.
10) TEMPERATURE
The temperature measured on the aluminium heat sink holding the MOSFET
devices.
11) MOTOR TEMPERATURE
This is the temperature of the motor; if the option is programmed "None" (see
chapter 8.4.2) it shows 0°.
12) HANDLE/SEAT switch
The level of the Handle/Seat digital entry
-
ON / GND = active entry of closed switch.
-
OFF / +VB = non active entry of open switch.
13) LIFTING CONTROL
The voltage of the lift potentiometer's wiper (CPOT). The voltage level is
shown on the Left Hand Side of the Console Display and the value in
percentage is shown on the Right Hand Side.
14) LIFT ENABLE
Status of the lifting switch.
Summary of Contents for ACE2
Page 7: ...AF2ZP0CL ACE2 User Manual Page 7 85 2 3Block diagram...
Page 28: ...Page 28 85 AF2ZP0CL ACE2 User Manual 7 3Connection drawing Traction configuration...
Page 29: ...AF2ZP0CL ACE2 User Manual Page 29 85 7 4Connection drawing Pump configuration...
Page 30: ...Page 30 85 AF2ZP0CL ACE2 User Manual 7 5Connection drawing Combi configuration...
Page 33: ...AF2ZP0CL ACE2 User Manual Page 33 85 8 3 2 Pump configuration...